Study on clinical application of susceptibility weighted imaging ombined with diffusion weighted imaging in patients with Liver Cirrhosis complicated with small Hepatocellular Carcinoma

  • Zhi-bo Hou
  • Fei Zhao
  • Bin Zhang
  • Chun-zhu Zhang China Academy of Chinese Medical Sciences
Keywords: Susceptibility weighted imaging, Diffusion weighted imaging, Liver cirrhosis, Small hepatocellular carcinoma, Diagnosis

Abstract

Objectives: To evaluate the clinical value of susceptibility weighted imaging (SWI) combined with diffusion weighted imaging (DWI) in patients with liver cirrhosis complicated with small hepatocellular carcinoma (SHCC).

Methods: A total of 40 patients with liver cirrhosis and 44 nodules were treated with conventional nuclear magnetic scanning (T1WI, T2WI) and SWI combined with DWI; the results were judged by two senior physicians; the t test, χ2 test, rank sum test, and other methods were used for contrastive analysis of the pathological results of different scanning methods after operation or puncture.

Results: Contrast analysis of the different MRI scanning methods and pathological results showed that among the 32 nodules of small hepatocellular carcinoma, 24 cases were diagnosed by conventional MRI, with the coincidence rate being 75%, 30 cases were diagnosed by SWI DWI, with the coincidence rate being 96%; significant difference was found between the two groups (p=0. 04). Significant differences were found in the specificity, sensitivity and accuracy of different scanning methods in the diagnosis of small hepatocellular carcinoma (specificity, accuracy, p=0.04; sensitivity p=0.01). The SWI of small hepatocellular carcinoma nodules showed hyperintensity, and the degree of iron deposition was low. Significant difference was found between small hepatocellular carcinoma nodules and other nodules (comparison of SWI signal degree, p=0.01; comparison of iron deposition degree, p=0.00).

Conclusion: The SWI of small hepatocellular carcinoma nodules showed hyperintensity, and the degree of iron deposition was low. The coincidence rate of SWI+DWI scanning is higher than that of conventional scanning methods in the diagnosis of small hepatocellular carcinoma, and the difference in specificity, sensitivity and accuracy has obvious advantages. SWI+DWI scanning can improve the detection rate of liver cirrhosis complicated with small hepatocellular carcinoma.

doi: https://doi.org/10.12669/pjms.37.3.3822

How to cite this:
Hou ZB, Zhao F, Zhang B, Zhang CZ. Study on clinical application of susceptibility weighted imaging combined with diffusion weighted imaging in patients with Liver Cirrhosis complicated with small Hepatocellular Carcinoma. Pak J Med Sci. 2021;37(3):800-804. doi: https://doi.org/10.12669/pjms.37.3.3822

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Published
2021-03-26
How to Cite
Hou, Z.- bo, Zhao, F., Zhang, B., & Zhang, C.- zhu. (2021). Study on clinical application of susceptibility weighted imaging ombined with diffusion weighted imaging in patients with Liver Cirrhosis complicated with small Hepatocellular Carcinoma. Pakistan Journal of Medical Sciences, 37(3). https://doi.org/10.12669/pjms.37.3.3822
Section
Original Articles