Correlation of blood pressure and the ratio of S1 to S2 as measuredby esophageal stethoscope and wireless bluetooth transmission

Authors

  • Kyoung Hoon Lim Chungbuk National University Hospital
  • Young Duck Shin Chungbuk National University Hospital
  • Sang Hi Park Chungbuk National University Hospital
  • Jin Ho Bae Chungbuk National University Hospital
  • Hong Jae Lee Chungbuk National University Hospital
  • Seon Jung Kim Hankook General Hospital
  • Ji Yun Shin Chungbuk National University Hospital
  • Young Jin Choi Eulji University Hospital

DOI:

https://doi.org/10.12669/pjms.294.3639

Keywords:

Blood pressure, Esophageal, Heart sounds, Stethoscope.

Abstract

Objective: Esophageal stethoscope has the advantage of being non-invasive, easily placed and capability to monitor the heart sound. This study was designed to determine whether the ratio of S1 to S2 analyzed by esophageal stethoscope and wireless bluetooth transmission can be accurate indicator that express the correlation with blood pressure.

Methods: Total 33 adult male and female without cardiac disorder and with normal heart rhythm were selected randomly as the subjects of this Study. Two microphones were used with one for acquisition of heart sound by connecting it to the esophageal stethoscope while the other was used to measure the background noise in the operating room. After having transmitted the heart sound measured with the esophageal stethoscope to the receiver by using bluetooth module, it was saved in PC and outputted, following removal of noise in the operating room and the respiratory sound. S1 and S2 were measured with computation of the ratio of S1 to S2. Correlations between the systolic blood pressure with each of the S1, S2 and ratio of S1 to S2 were examined by using correlation analysis.

Results: The ratio of S1 to S2 displayed the highest correlation with the systolic blood pressure, with S1 and S2 also displaying positive correlation with the systolic blood pressure.

Conclusion: As the result of analysis of the heart sound and the systolic blood pressure measured by using the esophageal stethoscope, the radio of S1 to S2 displayed greater correlation with the systolic blood pressure in comparison to the S1.

doi: http://dx.doi.org/10.12669/pjms.294.3639

How to cite this:Lim KH, Shin YD, Park SH, Bae JH, Lee HJ, Kim SJ, et al. Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission. Pak J Med Sci 2013;29(4):1023-1027.

Author Biographies

Kyoung Hoon Lim, Chungbuk National University Hospital

Department of Anesthesiology and Pain Medicine

Young Duck Shin, Chungbuk National University Hospital

Department of Anesthesiology and Pain Medicine

Sang Hi Park, Chungbuk National University Hospital

Department of Anesthesiology and Pain Medicine

Jin Ho Bae, Chungbuk National University Hospital

Department of Anesthesiology and Pain Medicine

Hong Jae Lee, Chungbuk National University Hospital

Department of Anesthesiology and Pain Medicine

Seon Jung Kim, Hankook General Hospital

Department of Anesthesiology and Pain Medicine

Ji Yun Shin, Chungbuk National University Hospital

Department of Biomedical Engineering

Young Jin Choi, Eulji University Hospital

Department of Surgery

Downloads

Published

2013-07-03

How to Cite

Lim, K. H., Shin, Y. D., Park, S. H., Bae, J. H., Lee, H. J., Kim, S. J., … Choi, Y. J. (2013). Correlation of blood pressure and the ratio of S1 to S2 as measuredby esophageal stethoscope and wireless bluetooth transmission. Pakistan Journal of Medical Sciences, 29(4). https://doi.org/10.12669/pjms.294.3639