Comparison of effectiveness and cost of patent ductusarteriosus device occlusion versus surgical ligationof patent ductus arteriosus

Authors

  • Arif Zulqarnain Ch. Pervaiz Elahi Institute of Cardiology Multan
  • Muhammad Younas Ch. Pervaiz Elahi Institute of Cardiology Multan
  • Tariq Waqar Ch. Pervaiz Elahi Institute of Cardiology Multan
  • Ahsan Beg Ch. Pervaiz Elahi Institute of Cardiology Multan
  • Touseef Asma Ch. Pervaiz Elahi Institute of Cardiology Multan.
  • Mirza Ahmad Raza Baig Ch. Pervaiz Elahi Institute of Cardiology Multan.

DOI:

https://doi.org/10.12669/pjms.324.10048

Keywords:

Surgical ligation, Patent ductus arteriosus.

Abstract

Objectives: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA.

Methods: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant.

Results: There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality.

Conclusion: The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.

doi: http://dx.doi.org/10.12669/pjms.324.10048

How to cite this:Zulqarnain A, Younas M, Waqar T, Beg A, Asma T, Baig MAR. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus. Pak J Med Sci. 2016;32(4):974-977.

Author Biographies

Arif Zulqarnain, Ch. Pervaiz Elahi Institute of Cardiology Multan

Fellow Paeds Cardiology

Muhammad Younas, Ch. Pervaiz Elahi Institute of Cardiology Multan

Assistant Professor and Head of Paeds Cardiology Department

Tariq Waqar, Ch. Pervaiz Elahi Institute of Cardiology Multan

Associate Professor Cardiac Surgery

Ahsan Beg, Ch. Pervaiz Elahi Institute of Cardiology Multan

Assistant Professor Paeds CardiologyAssistant Professor Peads Cardiology

Touseef Asma, Ch. Pervaiz Elahi Institute of Cardiology Multan.

Senior Registrar Paeds CardiologySenior Registrar Paeds Cardiology

Mirza Ahmad Raza Baig, Ch. Pervaiz Elahi Institute of Cardiology Multan.

Clinical Perfusionist, Cardiac Surgery Department

Downloads

Published

2016-08-13

How to Cite

Zulqarnain, A., Younas, M., Waqar, T., Beg, A., Asma, T., & Ahmad Raza Baig, M. (2016). Comparison of effectiveness and cost of patent ductusarteriosus device occlusion versus surgical ligationof patent ductus arteriosus. Pakistan Journal of Medical Sciences, 32(4). https://doi.org/10.12669/pjms.324.10048